- ClassificationCategoryOperational ResilienceDomainCybersecurityFramework FamilyOther
- Regulatory ContextTypeStandardLegal InstrumentStandardSectorEnergy SectorIndustryEnergy & Utilities
- Region / PublisherRegionNorth AmericaRegion DetailUnited States (FERC-approved, with U.S. effective dates); NERC covers the North American bulk electric systemPublisherNorth American Electric Reliability Corporation (NERC); approved by FERC under Federal Power Act section 215
- VersioningVersionCIP-002 through CIP-015 (each standard has its own version; the 2028 virtualization set runs from CIP-002-8 to CIP-013-3)Effective DateSet per standard: CIP-003-9 April 1, 2026; CIP-012-2 July 1, 2026; virtualization set July 1, 2028; CIP-014-4 and CIP-015-1 October 1, 2028Issue DateFebruary 7, 2008 (Order No. 706, 73 FR 7368, effective April 7, 2008, approving CIP-002-1 to CIP-009-1)
- AdoptionAdoption ModelRegulatory ComplianceImplementation ComplexityHigh
- Official ReferenceOpen Link in New TabSource
License included / downloadable: Yes
The CIP Reliability Standards are free PDFs on NERC's website, and the FERC orders that approve them are public in the Federal Register; the platform links to the official text and does not reproduce it.
Framework text is licensed by its publisher and is included only where stated above.
- NERC CIP (CIP-002 through CIP-015) are the mandatory cybersecurity and physical security Reliability Standards for the North American bulk electric system.
- FERC approves them under section 215 of the Federal Power Act, and NERC and its Regional Entities enforce them against registered entities.
- Each standard carries its own version and effective date; CIP-003-9 applies from April 1, 2026 and CIP-012-2 from July 1, 2026.
- The virtualization revisions (CIP-002-8, CIP-003-10, CIP-004-8, and others) are listed for July 1, 2028.
- Responsible Entities categorize BES Cyber Systems as high, medium, or low impact under CIP-002, then apply the matching requirements.
Overview
The NERC Critical Infrastructure Protection (CIP) Reliability Standards, CIP-002 through CIP-015, are the mandatory cybersecurity and physical security standards for the North American bulk electric system. The Federal Energy Regulatory Commission (FERC) approves them under section 215 of the Federal Power Act, and the North American Electric Reliability Corporation (NERC), the Electric Reliability Organization, and its Regional Entities enforce them against registered entities. In June 2025 FERC counted about 1,673 U.S. entities subject to mandatory CIP compliance.
There is no single CIP version: each standard carries its own version and U.S. effective date. FERC approved the first eight CIP standards, CIP-002-1 through CIP-009-1, in Order No. 706 (73 FR 7368, February 7, 2008, effective April 7, 2008), and approved Version 5, CIP-002-5 through CIP-011-1, in Order No. 791 on November 22, 2013. NERC's U.S. effective-date lists show CIP-003-9 effective April 1, 2026 and CIP-012-2 effective July 1, 2026, and its Weekly Regulatory Updates for October 12 to 18, 2026 list the virtualization revisions (CIP-002-8, CIP-003-10, CIP-004-8 and the others) for July 1, 2028.
Responsible Entities, such as balancing authorities, generator owners and operators, reliability coordinators and transmission owners and operators, categorize their BES Cyber Systems as high, medium or low impact under CIP-002, then apply the requirements that match each category. NERC publishes Reliability Standard Audit Worksheets for its standards, and each requirement carries measures that describe the evidence an auditor can ask to see.
Why does it matter?
The CIP standards make cybersecurity a compliance matter for the owners and operators of the grid, with audits, violation risk factors and violation severity levels attached to each requirement. They concentrate effort where an attack could matter most, because the requirements scale with the impact category of each BES Cyber System, and they are changing now: the virtualization revisions, supply chain updates, internal network security monitoring and a revised physical security standard each have a dated U.S. effective date that entities must plan for.
Key benefits include:
- Impact-based scoping
CIP-002-5.1a Attachment 1 sets bright-line criteria for high, medium and low impact, such as 1500 MW generation groups and 300 MW load shedding thresholds.
- Fixed recurring duties
Examples are security patch evaluation at least every 35 calendar days (CIP-007-6 R2) and incident response plan testing at least every 15 calendar months (CIP-008-6 R2).
- Fast incident reporting
CIP-008-6 R4 requires notice to the E-ISAC and the U.S. federal center or its successor one hour after a Reportable Cyber Security Incident is determined.
- Supply chain accountability
CIP-013-2 requires a documented supply chain risk management plan for high and medium impact systems, reviewed by the CIP Senior Manager at least every 15 calendar months.
- Evidence by requirement
Each requirement has measures listing examples of evidence, which the audit worksheets follow.
How does it work?
The standards are organized by control area. CIP-002 categorizes BES Cyber Systems; CIP-003 sets security management controls and covers low impact systems; CIP-004 covers training, personnel risk assessment and access management; CIP-005 the Electronic Security Perimeter and remote access; CIP-006 physical security of BES Cyber Systems; CIP-007 system security management; CIP-008 incident reporting and response; CIP-009 recovery plans; CIP-010 configuration change management and vulnerability assessments; CIP-011 BES Cyber System Information; CIP-012 communications between Control Centers; CIP-013 supply chain risk management; CIP-014 physical security of transmission stations; and CIP-015 internal network security monitoring.
Within each standard, requirements apply by impact level. CIP-004-7 requires training at least every 15 calendar months, a personnel risk assessment within seven calendar years of the previous one and removal of access within 24 hours of a termination action. CIP-005-7 requires Interactive Remote Access through an Intermediate System and methods to determine active vendor remote access sessions. CIP-007-6 includes review of logged events at intervals no greater than 15 calendar days, and CIP-010-4 requires monitoring for baseline changes at least every 35 calendar days on high impact systems and a vulnerability assessment at least every 15 calendar months.
Change moves through FERC. Order No. 907 approved CIP-015-1 on June 26, 2025 and directed NERC to extend internal network security monitoring to EACMS and PACS outside the Electronic Security Perimeter. Order No. 918 approved CIP-003-11 for low impact BES Cyber Systems, and Order No. 919 approved the virtualization revisions to 11 standards, effective May 26, 2026. NERC lists CIP-003-11 for July 1, 2029, CIP-014-4 and CIP-015-1 for October 1, 2028 and CIP-015-2 for October 1, 2029, so entities hold several versions in view at once.
Key Elements
- BES Cyber System categorization (CIP-002)
High, medium and low impact ratings assigned using Attachment 1 criteria, which decide which later requirements apply.
- Personnel, perimeter and physical controls (CIP-004 to CIP-006)
Training and access management, the Electronic Security Perimeter with remote access controls, and a physical security plan with visitor control.
- System security and monitoring (CIP-007, CIP-010)
Ports and services, patching, malicious code prevention, security event monitoring, baselines and vulnerability assessments.
- Incident reporting and recovery (CIP-008, CIP-009)
Response plans, one-hour reporting of Reportable Cyber Security Incidents and recovery plans tested at least every 15 calendar months.
- Information and supply chain (CIP-011, CIP-013)
Protection of BES Cyber System Information and a supply chain risk management plan for high and medium impact systems.
- Control Center, substation and network monitoring (CIP-012, CIP-014, CIP-015)
Protection of data exchanged between Control Centers, transmission station physical security and internal network security monitoring.
What does it cover?
The standards apply to Responsible Entities named in each standard's applicability section. CIP-002-5.1a lists balancing authorities, certain distribution providers (for example owners of load shedding systems of 300 MW or more), generator operators, generator owners, interchange coordinators or authorities, reliability coordinators, transmission operators and transmission owners. Applicability inside a standard narrows by Facility and by impact rating, and facilities within an approved Nuclear Regulatory Commission security plan are excluded in standards such as CIP-014. The U.S. enforceable versions are those FERC approves; each standard's effective date is set in its implementation plan.
What are its objectives?
The CIP standards exist to protect the reliable operation of the bulk electric system against cyber and physical compromise.
Identify and categorize BES Cyber Systems so that protection is commensurate with the adverse impact of their loss, compromise or misuse (CIP-002 purpose).
Establish accountable security management controls that protect BES Cyber Systems against compromise that could lead to misoperation or instability (CIP-003 purpose).
Detect and report cyber security incidents and recover the reliability functions of BES Cyber Systems (CIP-008 and CIP-009).
Protect real-time data exchanged between Control Centers and transmission stations that could affect an Interconnection (CIP-012, CIP-014).
Improve the probability of detecting anomalous or unauthorized network activity (CIP-015 purpose).
Framework in Context
Section 215 of the Federal Power Act lets FERC certify an Electric Reliability Organization to develop mandatory, enforceable Reliability Standards, subject to FERC review, and FERC certified NERC. Reliability Standards may be enforced by the ERO under FERC oversight or by FERC directly. CIP Version 5 (Order No. 791) changed the model from identifying Critical Cyber Assets to categorizing BES Cyber Systems, drawing on the NIST Risk Management Framework. The CIP standards sit beside the NERC operations and planning standards.
Common Framework Mappings
Utilities map the CIP requirements to these frameworks to reuse evidence across regulatory, industrial control system and enterprise security programs.
Mapped frameworks include:
CIS Controls v8.1
IEC 62443
ISO 27001:2022
MITRE ATT&CK
NIS2 (EU 2022/2555)
NIST CSF 2.0
NIST 800-53 Rev.5
NIST SP 800-82
How SmartSuite Supports NERC CIP
SmartSuite provides the system for managing controls, evidence, mappings, assessments, and reporting.
Use Compliance Management to hold each CIP requirement, its measures and its evidence, IT Asset Management for the BES Cyber System inventory, Third Party Risk Management for CIP-013 supply chain plans, and Operational Resilience & Business Continuity for CIP-009 recovery plan tests, so the recurring 15-month, 35-day and 24-hour obligations stay on one calendar.
BES Cyber System Register
Record each BES Cyber System with its CIP-002 impact rating, Attachment 1 criterion, location, owner and associated EACMS, PACS and PCA, with a change history.
CIP Requirement Library
Load requirements and measures by standard and version with owners, effective dates and linked procedures and evidence, including the version scheduled for each later effective date.
Access and Change Evidence
Keep CIP-004 training and personnel risk assessment dates, 24-hour access removals, CIP-005 remote access records and CIP-010 baseline change reviews against their cadences.
Patching and Monitoring Cadence
Schedule the 35-day patch evaluations, 15-day log reviews and 15-month vulnerability assessments, and attach results to the requirement parts.
Incident Reporting and Recovery Tests
Track determination time for Reportable Cyber Security Incidents, the one-hour notice and next-calendar-day attempt notice, and the CIP-008 and CIP-009 test dates.
Audit Evidence Reporting
Report requirements, evidence, potential noncompliance and open mitigation by standard, entity and registered function.
Related frameworks

CIS Controls v8.1 is a prioritized set of 18 Controls and 153 Safeguards, in three Implementation Groups, with a new Govern function.

COBIT 2019 is ISACA's framework for governing and managing enterprise IT, with 40 objectives in five domains, six governance principles and 11 design factors.

ISO/IEC 27001:2022 specifies requirements for an information security management system: Clauses 4 to 10, risk treatment, the Statement of Applicability and 93 Annex A controls.

ISO/IEC 27002:2022 is the reference set of 93 information security controls in four themes, with attributes and implementation guidance, that supports an ISO/IEC 27001 ISMS.

MITRE ATT&CK is a free knowledge base of adversary tactics, techniques and sub-techniques from The MITRE Corporation, updated twice a year; the current release is v20.0.

NIST CSF 2.0 (CSWP 29, February 26, 2024) is the voluntary cybersecurity framework with six Functions including Govern, 22 Categories, 106 Subcategories, Profiles and Tiers.
Frequently Asked Questions For NERC CIP (Critical Infrastructure Protection Standards)
Registered entities that a standard calls Responsible Entities. CIP-002-5.1a lists balancing authorities, certain distribution providers, generator operators and owners, interchange coordinators or authorities, reliability coordinators, transmission operators and transmission owners, and each standard narrows this by facility and impact rating. In Order No. 918, FERC counted about 1,673 U.S. entities subject to mandatory CIP compliance as of June 2025.
CIP-002 requires each Responsible Entity to identify and categorize BES Cyber Systems using the bright-line criteria in Attachment 1. A high impact system includes one used at a Reliability Coordinator control center or at a balancing authority control center for generation of 3000 MW or more in a single Interconnection, and medium impact includes systems tied to generation groups of 1500 MW or more. Later standards set stricter requirements for high and medium impact systems than for low impact systems.
CIP-008-6 R4 requires notice to the E-ISAC and, in the United States, the federal center it names (NCCIC, or its successor) within one hour after determining that a Reportable Cyber Security Incident occurred, and by the end of the next calendar day after determining that an incident was an attempt to compromise an applicable system. The plan must be tested at least once every 15 calendar months.
Each standard has its own date. NERC lists CIP-003-9 as effective April 1, 2026 and CIP-012-2 as effective July 1, 2026. Its October 12 to 18, 2026 update lists the virtualization revisions (CIP-002-8, CIP-003-10, CIP-004-8, CIP-005-8, CIP-006-7.1 through CIP-011-4.1 and CIP-013-3) for July 1, 2028, CIP-014-4 and CIP-015-1 for October 1, 2028, CIP-003-11 for July 1, 2029 and CIP-015-2 for October 1, 2029.
CIP-015-1 requires internal network security monitoring inside the Electronic Security Perimeter of high impact BES Cyber Systems and medium impact systems with External Routable Connectivity: monitor network data feeds (R1), retain data on activity judged anomalous until the action is complete (R2) and protect the collected data (R3). FERC approved it in Order No. 907 on June 26, 2025 and directed NERC to extend it to EACMS and PACS outside the perimeter, which is the purpose of CIP-015-2.