Cybersecurity

Saudi Arabia OTCC-1:2022

OTCC-1:2022 framework badge
Summarize with
ClaudeChatGPTPerplexityGoogle AI Mode
In this article
At a Glance
Saudi OTCC-1:2022
  • Classification
    Category
    Cybersecurity
    Domain
    Cybersecurity
    Framework Family
    Other
  • Regulatory Context
    Type
    Control Framework
    Legal Instrument
    Standard
    Sector
    Critical Infrastructure
    Industry
    Critical Infrastructure
  • Region / Publisher
    Region
    Middle East
    Region Detail
    Saudi Arabia
    Publisher
    National Cybersecurity Authority (NCA)
  • Versioning
    Version
    OTCC-1:2022
    Effective Date
    2022
    Issue Date
    2022
  • Adoption
    Adoption Model
    Regulatory Compliance
    Implementation Complexity
    High
  • Official Reference
License Information

License included / downloadable: Yes

The National Cybersecurity Authority publishes the OTCC-1:2022 PDF as a public document (Document Classification: Public, Sharing Notice: White) on its regulatory documents page; the Arabic version is the binding text.

Framework text is licensed by its publisher and is included only where stated above.

Official Resources
Operational Technology Cybersecurity Controls (OTCC‑1:2022)
Defines the minimum cybersecurity requirements for operational technology and industrial control systems.
Operational Technology Cybersecurity Controls Methodology and Mapping Annex (OTCC‑1:2022)
Provides methodology and mapping details aligning OTCC‑1:2022 with related standards and frameworks.
Key takeaways
  • OTCC-1:2022 is the Saudi NCA's cybersecurity requirements for industrial control systems in critical facilities.
  • It holds 4 domains, 23 subdomains, 47 main controls, and 122 subcontrols, implemented as an extension to the ECC.
  • Every control is marked for Level 1, 2, or 3, set by the OTCC Facility Level Identification Tool.
  • Level 1 carries 151 controls and subcontrols, Level 2 carries 117, and Level 3 carries 56.
  • Safety Instrumented Systems appear by name, change management has its own subdomain, and risk assessment feeds the Process Hazard Analysis.

Overview

The Operational Technology Cybersecurity Controls (OTCC-1:2022) are the National Cybersecurity Authority's cybersecurity requirements for industrial control systems in critical facilities. They were issued in 2022 for government organizations and for private sector organizations that own, operate or host Critical National Infrastructures, in the Kingdom or abroad. They are implemented as an extension to the Essential Cybersecurity Controls, and compliance with the ECC is a mandatory prerequisite (Executive Summary; Implementation and Compliance). The document contains 4 main domains, 23 subdomains, 47 main controls and 122 subcontrols (Introduction), and the term industrial control systems covers all devices, systems or networks used to operate or automate industrial processes.

What sets the OTCC apart from the other NCA control sets is the level column. Every control is marked for Level 1, Level 2 or Level 3, and the level a facility must meet comes from the OTCC Facility Level Identification Tool, which weighs the criticality and impact on the organization's business and service availability, the impact on health, safety and environment, and the impact on the national economy, national security or society. Table 1 gives the totals: L1, for facilities whose criticality is high, carries 151 controls and subcontrols including the L2 and L3 sets; L2, moderate criticality, carries 117 including L3; L3, low criticality, carries 56.

Organizations apply the OTCC by assigning a level to each critical facility with the identification tool, implementing every applicable control at that level after confirming that applying it will not jeopardize the continuity of operations (Statement of Applicability), and keeping compliance continuous under item 3 of Article 10 of the NCA mandate and Royal Decree 57231 of 10/11/1439H. The NCA evaluates compliance through self-assessment and audit field visits by the NCA or designated third parties, and issues an OTCC-1:2022 Assessment and Compliance Tool for the purpose (Implementation and Compliance). The NCA states that the Arabic version governs interpretation.

Why does it matter?

Plant networks fail differently from office networks: a bad change can stop production or defeat a safety system, so the OTCC writes safety into cybersecurity. Safety Instrumented Systems appear by name in the controls on system protection, network segmentation and physical access; change management has its own subdomain; and risk assessment must feed the Process Hazard Analysis that plants already run. The controls also recognize that some requirements cannot be applied in an OT environment, and instead of silence they require the justification to be documented and approved by the cybersecurity function and the Authorizing Official (1-3-1-6), with alternative controls defined for a set period when a risk is accepted (1-3-1-7).

Key benefits include:

  • Safety systems are treated as crown jewels

Safety Instrumented Systems controllers must stay in modes that prevent unauthorized changes (2-3-1-5), must be segmented from other OT networks (2-4-1-3), and physical access to them is strictly limited (2-13-1-5); qualitative cyber risk analysis joins the Process Hazard Analysis for any change in plant operations (1-3-1-5).

  • Zones, choke points and a DMZ jump host

The OT environment is segmented from other networks (2-4-1-1), zones inside it are segmented by level with traffic directed to choke points (2-4-1-2), wireless is restricted and segmented (2-4-1-4, 2-4-1-5), and direct corporate-to-OT communication is prevented, with required connections routed through a dedicated hardened jump host in the DMZ (2-4-1-9).

  • OT identities separate from IT

Identity and access management for OT is separated and independent from IT, including the central solutions (2-2-1-1); service accounts are separated from interactive logins (2-2-1-2); default credentials are changed, disabled or removed (2-2-1-3); dual approval applies to sensitive actions (2-2-1-6); and remote access is exceptional, risk-assessed, multi-factor, encrypted, time-limited, monitored and recorded (2-2-1-7).

  • An inventory with owners and criticality

An electronic OT asset inventory is required and reviewed periodically (2-1-1-1), collected with an automated solution (2-1-1-2), stored securely (2-1-1-3), with an owner for every asset (2-1-1-4) and a criticality rating approved by that owner (2-1-1-5).

  • Resilience in safe mode

Minimum-operation activities are defined (3-1-1-1), redundancy follows the risk assessment (3-1-1-2), OT requirements enter the BCP, BIA, RTO and RPO (3-1-1-3) and the DRP (3-1-1-4), assets must fall to an acceptable safe mode after a cyber incident (3-1-1-5), and tabletop exercises test the plans (3-1-1-6).

How does it work?

Scope is defined by facility, not by sector. The controls apply to industrial control systems that reside in facilities deemed critical and owned or operated by government organizations (ministries, authorities, establishments and others) or by private sector organizations owning, operating or hosting Critical National Infrastructures, whether in the Kingdom or abroad; a critical facility is one whose destruction or dysfunction may disrupt or discontinue the organization's operation (Scope of Work). Other organizations are encouraged to use the controls. The Statement of Applicability then requires every in-scope organization that owns or operates ICS to comply with all applicable controls, after ensuring that applying them will not jeopardize operational continuity.

Levels decide how much of the document applies. The three criteria behind the levels are criticality and impact on business and service availability, impact on health, safety and environment, and impact on the national economy, national security or society (OTCC Controls and Sub-controls Levels). The Facility Level Identification Tool assigns L1, L2 or L3 to each facility, and risk control 1-3-1-4 requires that assignment to follow an approved methodology. Each control in the body carries an L1, L2, L3 marking, and Table 1 totals them at 151, 117 and 56 controls and subcontrols respectively, each higher level including the lower ones; the subcontrol-level detail sits in the Methodology and Mapping Annex.

Every OTCC control is written against an ECC reference. Policies and procedures refer to ECC controls 1-3-1 to 1-3-4, roles and responsibilities add to ECC subdomain 1-4 with a RACI for all OT stakeholders approved by the Authorizing Official (1-2-1-1), risk management adds to ECC subdomain 1-5, and project management adds to ECC controls 1-6-2 and 1-6-3 with cybersecurity in factory and site acceptance testing, commissioning and source code review (1-4-1-2) and secure-by-design architecture (1-4-1-3). Review follows the ECC pattern: the cybersecurity function reviews OTCC implementation at least annually (1-6-1) and independent parties outside it review it at least every three years (1-6-2), with reference to ECC controls 1-8-1 and 1-8-2.

Key Elements

  • Domain 1, Cybersecurity Governance

Eight subdomains: 1-1 Cybersecurity Policies and Procedures, 1-2 Cybersecurity Roles and Responsibilities, 1-3 Cybersecurity Risk Management, 1-4 Cybersecurity in Industrial Control System Project Management, 1-5 Cybersecurity in Change Management, 1-6 Periodical Cybersecurity Review and Audit, 1-7 Cybersecurity in Human Resources and 1-8 Cybersecurity Awareness and Training Program.

  • Domain 2, Cybersecurity Defense

Thirteen subdomains: 2-1 Asset Management, 2-2 Identity and Access Management, 2-3 System and Processing Facilities Protection, 2-4 Networks Security Management, 2-5 Mobile Devices Security, 2-6 Data and Information Protection, 2-7 Cryptography, 2-8 Backup and Recovery Management, 2-9 Vulnerabilities Management, 2-10 Penetration Testing, 2-11 Cybersecurity Event Logs and Monitoring Management, 2-12 Cybersecurity Incident and Threat Management and 2-13 Physical Security.

  • Domain 3, Cybersecurity Resilience

3-1 Cybersecurity Resilience Aspects of Business Continuity Management (BCM), with six minimum requirements from minimum-operation activities to tabletop exercises and root cause analysis (3-1-1-1 to 3-1-1-6).

  • Domain 4, Third-Party Cybersecurity

4-1 Third-Party Cybersecurity, covering manufacturers of OT hardware and software, vendors of OT products and suppliers of OT services: cybersecurity in the procurement life cycle, evaluation and information-sharing requirements, a documented secure development life cycle for anything deployed in OT, and periodic assessments and audits of providers (4-1-1-1 to 4-1-1-4).

  • Change management (1-5)

Changes are validated in a separate environment before production (1-5-3-2), functionally equivalent replacement devices are validated before use (1-5-3-3), exceptional changes follow a restricted process (1-5-3-4) and automated configuration and asset change detection is in place (1-5-3-5).

  • System protection (2-3)

Advanced malware and APT protection (2-3-1-1), vendor-aligned hardening and patching under formal change management (2-3-1-2, 2-3-1-3), least privilege and least functionality (2-3-1-4), application whitelisting (2-3-1-6), dedicated hardened engineering workstations and HMIs (2-3-1-7) and scanning and restriction of external storage media (2-3-1-8, 2-3-1-9).

  • Cryptography and people

Cryptographic technologies in OT must align with the NCA National Cryptographic Standard NCS1:2020 (2-7-1); all personnel with OT access are screened before access (1-7-1) and receive customized training, with the Saudi Cybersecurity Workforce Framework recommended as reference material (1-8-2-1).

  • Control levels, tools and annex

The L1, L2 and L3 scheme with Table 1 totals, the Facility Level Identification Tool, the Assessment and Compliance Tool, the Methodology and Mapping Annex, and Appendices (A) Terms and Definitions and (B) List of the Abbreviations.

What does it cover?

The OTCC applies to industrial control systems that reside in critical facilities owned or operated by government organizations, including ministries, authorities and establishments, and by private sector organizations owning, operating or hosting Critical National Infrastructures, whether in the Kingdom or abroad, all referred to as the Organization (Scope of Work). A critical facility is defined as one whose destruction or dysfunction may lead to the disruption or discontinuity of the organization's operation, and industrial control systems means all devices, systems or networks used to operate or automate industrial processes. The level assigned by the Facility Level Identification Tool then determines whether the 151, 117 or 56 controls and subcontrols of L1, L2 or L3 apply (Table 1).

What are its objectives?

The Objectives section states what the controls are for:

To extend the ECC so that national cybersecurity goals are met in industrial control systems by defining their cybersecurity requirements (Objectives).

To let national organizations fulfill mandated cybersecurity requirements that raise the protection of critical infrastructure and its readiness against cyber risks (Objectives).

To address the four cybersecurity pillars of Strategy, People, Process and Technology in the OT environment (Objectives).

To draw on international OT and ICS cybersecurity guidance, standards and controls studied during development (Introduction).

To keep production uptime and safe operations alongside the confidentiality, integrity and availability of OT assets (objective of subdomain 2-1).

Framework in Context

The OTCC is where the NCA's industrial control systems requirements now live. ECC-1:2018 carried them as main domain 5, Industrial Control Systems Cybersecurity; the ECC-2:2024 edition deleted that domain and records in Appendix (C) that its controls moved to the OTCC, so the OTCC references to ECC-1:2018 control numbers should be read against the 2024 text. The Critical Systems Cybersecurity Controls (CSCC-1:2019) cover critical information systems rather than industrial ones, and an operator can be in scope of both. The OTCC also points to two other NCA instruments: the National Cryptographic Standard NCS1:2020 for cryptography in OT (2-7-1) and the Saudi Cybersecurity Workforce Framework for training (1-8-2-1).

Common Framework Mappings

Operators that already follow international OT security standards map the OTCC subdomains to them, and the document's own Methodology and Mapping Annex describes its relationships to those standards.

Mapped frameworks include:

CIS Controls v8.1

IEC 62443

ISO 27001:2022

ISO 27002:2022

NERC CIP

NIST CSF 2.0

NIST 800-53 Rev.5

PCI DSS 4.0.1

SOC 2

SMARTSUITE

How SmartSuite Supports OTCC-1:2022

SmartSuite provides the system for managing controls, evidence, mappings, assessments, and reporting.

Use IT Asset Management (ITAM) for the electronic OT asset inventory with owners and criticality ratings that controls 2-1-1-1 to 2-1-1-5 require, Compliance Management to hold the 47 main controls and 122 subcontrols with their L1, L2 and L3 markings and ECC references, and Operational Resilience & Business Continuity for the BCP, BIA, RTO, RPO and DRP requirements of 3-1-1-3 and 3-1-1-4.

Facility Level Register

Record each critical facility, the outcome of the Facility Level Identification Tool against the three criteria, the approved methodology behind it (1-3-1-4) and the resulting L1, L2 or L3 control set.

Leveled Control Library

Hold every OTCC control with its level marking and its ECC reference so that an L2 facility sees exactly its 117 controls and subcontrols and the evidence for the ECC prerequisite sits beside them.

Exceptions and Risk Acceptance

Use Cyber & IT Risk to document any requirement that cannot be applied in the OT environment with its justification and approvals (1-3-1-6), and the alternative controls, period and reassessment dates for accepted risks (1-3-1-7).

OT Asset Inventory

Use IT Asset Management (ITAM) to keep the OT inventory in electronic form with owner, criticality rating and review date (2-1-1-1 to 2-1-1-5), including Safety Instrumented Systems and engineering workstations.

Change and Remote Access Records

Log OT changes with their separate-environment validation (1-5-3-2) and device replacement checks (1-5-3-3), and each remote access grant with its risk assessment, duration, privileges and session recording (2-2-1-7).

Third-Party and Review Evidence

Use Third Party Risk Management for vendor SDLC evidence and periodic assessments (4-1-1-3, 4-1-1-4), and Internal Audit Management for the annual (1-6-1) and three-yearly independent (1-6-2) reviews the NCA may request.

Related frameworks

IEC 62443-4-2

IEC 62443-4-2:2019 sets technical security requirements for IACS components, with seven foundational requirements and security levels 1 to 4.

ISO 27001:2022

ISO/IEC 27001:2022 specifies requirements for an information security management system: Clauses 4 to 10, risk treatment, the Statement of Applicability and 93 Annex A controls.

ISO 27002:2022

ISO/IEC 27002:2022 is the reference set of 93 information security controls in four themes, with attributes and implementation guidance, that supports an ISO/IEC 27001 ISMS.

NIST 800-53 Rev.5

NIST SP 800-53 Rev. 5 is the NIST catalog of security and privacy controls in 20 families, mandatory for federal systems under OMB A-130 and FISMA; Release 5.2.0 issued August 27, 2025.

NIST CSF 2.0

NIST CSF 2.0 (CSWP 29, February 26, 2024) is the voluntary cybersecurity framework with six Functions including Govern, 22 Categories, 106 Subcategories, Profiles and Tiers.

NIST 800-82 Rev.3 Moderate OT

Moderate baseline of the NIST SP 800-82 Rev. 3 OT overlay: SP 800-53B moderate controls tailored for moderate-impact OT systems, with the Appendix F additions, removals and tailoring rules.

SOC 2

SOC 2 is the AICPA examination, under AT-C 105 and 205, of a service organization's controls against the 2017 Trust Services Criteria, issued as a type 1 or type 2 attestation report.

FAQ

Frequently Asked Questions For Saudi Arabia OTCC-1:2022 (Operational Technology Cybersecurity Controls)

Industrial control systems that reside in critical facilities owned or operated by government organizations or by private sector organizations owning, operating or hosting Critical National Infrastructures, in the Kingdom or abroad (Scope of Work). A critical facility is one whose destruction or dysfunction may disrupt or discontinue the organization's operation, and industrial control systems means all devices, systems or networks used to operate or automate industrial processes. Other organizations are encouraged to adopt the controls.

The OTCC Facility Level Identification Tool assigns each critical facility Level 1, 2 or 3 based on the criticality and impact on business and service availability, the impact on health, safety and environment, and the impact on the national economy, national security or society. Table 1 gives the totals: L1 (high criticality) 151 controls and subcontrols including L2 and L3, L2 (moderate) 117 including L3, and L3 (low) 56. Every control in the document carries its level marking.

The OTCC is implemented as an extension to the Essential Cybersecurity Controls, and compliance with the ECC is a mandatory prerequisite (Implementation and Compliance). Each OTCC control is written against an ECC reference, for example policies and procedures against ECC 1-3-1 to 1-3-4 and asset management against ECC subdomain 2-1. The Methodology and Mapping Annex describes the relationship to ECC domain 5, the industrial control systems domain of ECC-1:2018 that ECC-2:2024 removed and moved into the OTCC.

The OT environment must be segmented logically or physically from other networks (2-4-1-1), zones inside it segmented by level with traffic directed through choke points (2-4-1-2), Safety Instrumented Systems segmented from other OT networks (2-4-1-3), wireless restricted and segmented (2-4-1-4, 2-4-1-5), and direct corporate-to-OT communication prevented with connections routed through a hardened jump host in the DMZ (2-4-1-9). Remote access is restricted and enabled only when justified, after a risk assessment, through a multi-factor authenticated and encrypted channel for a defined period with limited privileges, and the session is monitored and recorded (2-2-1-7).

All in-scope organizations must comply with the applicable controls at the appropriate level under item 3 of Article 10 of the NCA mandate and Royal Decree 57231 of 10/11/1439H. The NCA evaluates compliance through self-assessment by the organization and audit field visits by the NCA or designated third parties, and issues an OTCC-1:2022 Assessment and Compliance Tool to organize the evaluation. Internally, the cybersecurity function reviews implementation at least annually (1-6-1) and independent parties review it at least every three years (1-6-2).